Pagina 1 - Pen Reader

MS100 Bar CodePen ReaderRev.A

Pagina 2 - AdventureJan

6MS100 ManualBeep ToneSelect a value from “None” to “High” to set the loudness of the tone,or select “Low to High” or “High to Low” to set the charact

Pagina 3 - FCC Information

7MS100 ManualKeyboard WedgeYour Unitech keyboard contains a built in data decoder or “wedge”that translates raw bar code input into Keyboard Scan Code

Pagina 4 - TABLE OF CONTENTS

8MS100 ManualKeyboard Wedge, continuedUse Numeric KeypadThe ASCII code for numeric input from the keypad part of thekeyboard is different from that of

Pagina 5 - INTRODUCTION

9MS100 ManualBaud RateBaud Rate (bits per second) refers to the speed of the data throughthe RS232 port. If the data error rate is unacceptably high,

Pagina 6 - MS100 Manual2

10MS100 ManualData DirectionThree options are available for data direction: “Send to Host”,“Send to Host & Terminal”, and “Send to Terminal”.Defa

Pagina 7 - Start it Up

11MS100 ManualTerminatorThe Terminator is a command that follows the input of bar codedata. Four different terminators can be selected here: “Enter”

Pagina 8 - Download to your Scanner

12MS100 ManualAim Function for Long Range EngineThe Aim Function causes a laser scanner to output a “pin-point”aiming aid for a specified period of ti

Pagina 9 - First Look

13MS100 ManualAiming Time for Long Range EngineThe Aiming Time function specifies the duration of the Aim Function(see previous page). Length of dura

Pagina 10 - Settings

14MS100 ManualBar Code SymbologiesModify the output characteristics of 16 of the most popular bar codesymbologies in current use. Following are the b

Pagina 11 - Keyboard Wedge

15MS100 ManualBar Code Symbologies, continuedStandard 2 of 5 / Toshiba Code (China Postal Code)Maximum Length defines the maximum length the user will

Pagina 13 - MS100 Manual

16MS100 ManualBar Code Symbologies, continuedCode 128Enabled toggles the ability for the keyboard/scanner to readCode 128 on or off. Default is “Yes”

Pagina 14 - RS232, continued

17MS100 ManualBar Code Symbologies, continuedCode 93Enabled toggles the ability for the keyboard/scanner to readCode 93 on or off. Default is “Yes”.•

Pagina 15 - Scanner Port

18MS100 ManualBar Code Symbologies, continuedUPC-ASend Check Digit toggles whether or not to send a check digit.Default is “Send”.•Send Leading Digit

Pagina 16 - Scanner Port, continued

19MS100 ManualBar Code Symbologies, continuedEAN-8Send Check Digit toggles whether or not to send a check digit.Default is “Send”.•Send Leading Digit

Pagina 17

20MS100 ManualBar Code Symbologies, continuedCode 11Maximum Length defines the maximum length the user willaccept for a valid bar code. Default is “4

Pagina 18 - Bar Code Symbologies

21MS100 ManualBar Code Symbologies, continuedLabel Code IV and V•Enabled toggles the ability for the keyboard/scanner to readLabel Code IV and V on or

Pagina 19 - Interleaved 2 of 5

22MS100 ManualData EditingQualifierThe Qualifier section defines the conditions that must be present forthe bar code to be modified, such as what type

Pagina 20 - Code 128

23MS100 ManualData Editing, continuedDelete deletes existing modifier strings.Move Up / Move Down moves the modifiers up and downin relation to each o

Pagina 21 - MSI / Plessey Code

24MS100 ManualData Editing, continuedThe “Everything Else” FormulaIf a formula is entered into the Data Editing area, then all scannedbar codes will b

Pagina 22

25MS100 ManualPROGRAMMING VIA SCANNER INPUTIn addition to the Scanner Configuration Manager software, yourUnitech scanner can also be configured via b

Pagina 23

Improper handling, storage, environmental influences and /orproduct modification can lead to problems during use.This is particularly true if repairs

Pagina 24 - Delta Code

26 MS100 ManualQuick Setup Bar CodesDevice TypeUSBIBM TerminalKeyboardlessCode 39Wand EmulationSerial InterfaceTerminal WedgePC AT (PS/2)PS/2Macintosh

Pagina 25 - Label Code IV and V

27MS100 ManualQuick Setup Bar Codes, continuedDefaultCut Leading DigitSend Check DigitUPC-A ConversionUPC-EDefaultCut Leading DigitCut Check DigitEAN-

Pagina 26 - Data Editing

28 MS100 ManualDevice Selection and Default28 - Dorio ANSI Keyboard00 - IBM PC/XT01 - IBM PC/AT, PS/2 MOD 40, 60, 80, USB etc.02 - IBM PS/2 MOD 30 (80

Pagina 27 - Data Editing, continued

29MS100 ManualBeeps and DelaysInterblock Delay: (see page 6)0 - 0 ms1 - 10 ms2 - 50 ms3 - 100 ms4 - 500 ms5 - 1 seconds6 - 3 seconds7 - 5 secondsBeep

Pagina 28

30 MS100 ManualKeyboard InterfaceCaps-Lock: (see page 7)0 - Auto Trace (PC/AT)1 - Lower Case 2 - Upper CaseFunction Code: (see page 7)0 - Off 1

Pagina 29 - PROGRAMMING VIA SCANNER INPUT

RS232Group DefaultEnter Group 40123456789C1Baud Rate:0 = 300 4 = 48001 = 600 5 = 96002 = 1200 6 = 192003 = 2400 7 = 38400C2Parity:2 = Mark0 = Even 3 =

Pagina 30 - Quick Setup Bar Codes

C7Time Out (for serial wedge)0 = 1 second1 = 3 seconds2 = 10 seconds3 = UnlimitedC8Data Direction (for Terminal Wedge)0 = Send to Host1 = Send to Host

Pagina 31 - 27MS100 Manual

33MS100 ManualScanner Port0123456789Group DefaultEnter Group 5Code ID: (see page 11)Note: This setting does not affect EAN128Code ID. EAN128 has its

Pagina 32 - Device Selection and Default

34 MS100 ManualScanner Port, continued0 - Positive 1 - Positive and NegativeLabel Type: (see page 12)0 - Disable 1 - EnableAim Functio

Pagina 33 - Beeps and Delays

35MS100 ManualSymbologies:Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / Telpen / UCC/EAN128Group DefaultEnter Group 60123456789:Standard 2 of 5China Posta

Pagina 34 - Keyboard Interface

TABLE OF CONTENTSRS232 31. . . . . . . . . . . . . . . . . . . .Scanner Port 33. . . . . . . . .

Pagina 35

36 MS100 ManualCode 39 / I 2 of 5 / S 2 of 5 / Code 32 / Telpen / UCC/EAN128, continued0123456789ExitMMMin. LengthNNMax. LengthTo define minimum or ma

Pagina 36

37MS100 ManualSymbologies:Code 128 / MSI / Code 93 / Code 11 / Codabar / Label Code0123456789Group DefaultEnter Group 7G10/1 - Disable / Enable1-64 -

Pagina 37

38 MS100 ManualCode 128 / MSI / Code 93 / Code 11 / Codabar / Label Code, continued0123456789Exit0/1 - Disable / Enable2/3 - Checksum send / No sendLa

Pagina 38

39MS100 ManualSymbologies:UPC / EAN / Delta Code0/1 - Disable / Enable2/3 - Check Digit Calculate / Not Calculate4/5 - Check Digit Send / No SendDelta

Pagina 39 - Symbologies:

40 MS100 ManualData Editing:Data Editing allows you to manipulate the bar code data output into a format thatyou require by scanning in the bar codes

Pagina 40 - 36 MS100 Manual

41MS100 ManualModifiers:Original Data - Part or all of the original data string can be selected. Theprogramming bar codes must be entered in the foll

Pagina 41

42 MS100 ManualData Editing, continuedCode Type:10 - S 2 of 519 - All Inputs18 - China Postal Code11 - MSI Code17 - Code 11(Special)16 - Plessey Code1

Pagina 42 - 38 MS100 Manual

43MS100 ManualFunction Codes for PC (Code 39)(Characters in parentheses represent Code 39 bar code printing)F1 (%VA)F4 (%VD)F7 (%VG)F10 (%VJ)Esc (/FK)

Pagina 43

44 MS100 ManualASCII Chart(Characters in parentheses represent Code 39 bar code printing)VT ($K)FF ($L)CR ($M)SO ($N)SI ($O)DLE ($P)DC1 ($Q)DC2 ($R)DC

Pagina 44 - Data Editing:

45MS100 ManualASCII Chart, continued(Characters in parentheses represent Code 39 bar code printing), (/L)-./0123456789: (/Z); (%F)< (%G)= (%H)>

Pagina 45

MS100 Manual 1INTRODUCTIONThe MS100 is a family of pen style bar code readers specifically designedto be a simple, unobtrusive method of scanning bar

Pagina 46

46 MS100 ManualASCII Chart, continued(Characters in parentheses represent Code 39 bar code printing)LMNOPQRSTUVWXYZ[ (%K)\ (%L)] (%M)^ (%N)_ (%O)&apos

Pagina 47 - Function Codes for PC

47MS100 ManualASCII Chart, continued(Characters in parentheses represent Code 39 bar code printing)a (+A)b (+B)c (+C)d (+D)e (+E)f (+F)g (+G)h (+H)i (

Pagina 48 - ASCII Chart

ENVIRONMENTAL-4° to 158° F (-20° to 70° C)Storage:Temperature: Operating: 32° to 131° F (0° to 55° C)Humidity: 20% to 85% RH non-condensingSPECIFICATI

Pagina 49 - ASCII Chart, continued

PINOUTSPin 1 N/CPin 2 TXD (Transmit Data)Pin 3 RXD (Receive Data)Pin 4 N/CPin 5 GND (Ground)Pin 6 N/CPin 7 CTS (Clear to Send)Pin 8 RTS (Request to Se

Pagina 50

TROUBLESHOOTINGMS100 Manual50Most problems that you might encounter with your scanner can besolved using the following procedures:Test the scanner on

Pagina 51

MS100 Manual 51Problems and SolutionsProblem: Scanner doesn’t light up.If the scanner does not emit a light when pluggedin, check the interface.If th

Pagina 52 - SPECIFICATIONS

MS100 Manual52Problems and SolutionsProblem: Scanner Configuration Manager cannot upload or download.Scanner Configuration Manager can currentlyu

Pagina 53 - MS100 Manual 49

53MS100 ManualLimited Hardware WarrantyThe Limited Warranty terms described below are solely applicable to the Cus-tomer of Unitech America, Inc’s (af

Pagina 54 - TROUBLESHOOTING

54 MS100 ManualBAR CODE TEST CHART8012 3453EAN-8Unitech 128Code 128A22357000599876BCodabar123456789-0Code 11Code 32AO23399013Code 93123ABC0123456Delta

Pagina 55 - Problems and Solutions

55MS100 Manual3 045214 834123EAN-130647669 13716UPC-A0212345799UPC-E(01)054123456789(01)659344EAN 1281234558MSI Code0987654321Interleaved 2 of 59 7895

Pagina 56

MS100 Manual2MS100-3The MS100-3 AT keyboard wedge interface has a “Y” interface cable withan AT male plug on one end and an AT female plug on the othe

Pagina 57 - WARRANTY

3MS100 ManualThe above icons, from left to right, represent download settings(from computer to scanner), and upload settings (from scanner tocomputer)

Pagina 58 - BAR CODE TEST CHART

MS100 Manual4The above four icons are used in the “Data Editing” feature of SCM.From left to right they are the “Add a Formula” icon, the “Remove aFor

Pagina 59

5MS100 ManualThe screen to the leftappears. Click on any ofthe selections under“Current Settings” to viewits “Attributes”.Click the upload icon (see