Unitech MS210 Manuale Utente

Navigare online o scaricare Manuale Utente per Lettori di codici a barre Unitech MS210. Unitech MS180 Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - User’s Manual

Hand Held ScannerUser’s ManualDate : January, 2000Version : 3.0

Pagina 2

Page 93.2 Understanding the Operating ParametersDevice TypeYou will need to select the device type to “Serial Interface” fromAppendix A, Group 1 of Ap

Pagina 3

Page 10BCC Character:BCC check character is calculated for entire data stream by using“Exclusive OR ” method. It is sent after data stream for dataver

Pagina 4 - Chapter 1 Overview

Page 11Chapter 4 Terminal Interface4.1 InstallationTo install the scanner as a terminal interface, you need a DB25 RS232cable, a terminal wedge “Y” ca

Pagina 5 - Chapter 2 Keyboard Interface

Page 124) If the scanner has not been configured yet, you need to select“Terminal Wedge” device number from Appendix A, Group 1 ofAppendix D, or the f

Pagina 6 - 2.3 Installed on Macintosh

Page 13Chapter 5 Wand Emulation5.1 InstallationFigure 4 shows how a wand emulation scanner is installed to a datacollection terminal. User needs to pa

Pagina 7 - Keyboard

Page 14Output of Wand Emulation: (Appendix D, 3)Select one of the two choices for the polarity of data output:* High level for bar (black) and low lev

Pagina 8

Page 15Chapter 6 SetupThe scanner interface can be configured to fit the user's specificapplication. All configuration parameters are stored in a

Pagina 9 - 3.1 Installation

Page 166.1.2 Bar Code Length Setting:The following example illustrates how to set Code 39 with a minimumlength of 5 and a maximum length of 20:* Scan

Pagina 10 - Serial Interface

Page 17Those ID characters can be redefined through setup menu. Thefollowing example shows how to set Code 93 with ID ‘O’ and Code128 without ID:* Sca

Pagina 11 - 3.3 Serial TTL

Page 18Here is an example how to define the output of “Label 0” as “START”,“Label 1” as “ACCEPT” and “Label 2” as “END”:* Scan “Enter Group 3”* Scan “

Pagina 12 - Chapter 4 Terminal Interface

CHAPTER 1 OVERVIEW... 3CHAPTER 2 KEYBOARD INTERFACE...

Pagina 13 - Terminal Wedge

Page 19The following label is called “Dump Settings” label. Before you scanthe label, please open a text editor application(such like, Notepad,Word, e

Pagina 14 - Chapter 5 Wand Emulation

Page 20The following issues should be observed:• The sequence of the strings that the scanner dumped is important. Youhave to print the bar code label

Pagina 15

Page 21Chapter 7 Output Data EditingThe function described here can be replaced by the “Pre-definedLabels” function in 6.1.5 Predefined Labels. So if

Pagina 16 - Chapter 6 Setup

Page 22FormularQualifier ModifierInput ID [Length] [Match] Input ID [Length] [Match] [Match] [Match]...A-String: String to be added.O-String: Modified

Pagina 17

Page 237.3.3. Programming SheetThe bold and italicized characters in following sections mean a barcodelabel on the Programming Sheet.EnterGroup 10Scan

Pagina 18

Page 24b) String ParametersA string is a set of characters, wild characters, or sequence ofadjacent characters enclosed in double quotation marks, whi

Pagina 19 - 6.3 Batch Setup

Page 257.4.2. Length:Format:LEN,Min,Max,Length field consists of two length parameters: minimum length (Min)and maximum length (Max). When defined, a

Pagina 20 - 0 8 0 8 0 A0 O7 C0 0 5 3 5 4

Page 26Checks if the original data has 'A' at position 3, 'B' at position '4' andlast character is '?'.MATCH ,

Pagina 21 - Dump Settings On PC/AT

Page 27-- If N greater than the number of remaining characters counting fromP, the remaining characters are included as valid.7.6. Examples7.6.1. Exam

Pagina 22 - Chapter 7 Output Data Editing

Page 28-- From the position next to 'i', search for k.-- If above searches are all found, the result of the parameter will be theposition wh

Pagina 23 - 7.3. Programming

Page 27.3.3. Programming Sheet ... 237.3.4. Parameter Entry...

Pagina 24

Page 29Chapter 8 Pin Assignment and Specification8.1 Pin AssignmentsThe modular connectorlocated at the bottom ofthe scanner handle hasthe pin numberi

Pagina 25 - 7.4. Qualifier

Page 30TTL RS232 Interface:The following table shows pinout for TTL RS232 interface at modularconnector:Pin Number Signal1 Not Used2 VCC(+5V, output)3

Pagina 26

Page 31DB9 Female (Front View)1569PinNumberSignal2 TXD3 RXD5 GND7 CTS8 RTS9 VCC8.1.3. Terminal InterfaceTo use the scanner as a terminal Interface, an

Pagina 27 - 7.5. Modifier

Page 32Terminal Side connectorThe connector for the terminal is a DB25 male and has followingpinout:DB25 Male (Front View)1131425PinNumberSignal2 RXD3

Pagina 28 - 7.7. Advanced Features

Page 33On the other end of the wand emulation cable is a squeeze releasedDB9 female connector. The pinout for this connector is:Pin Number Signal1 Not

Pagina 29

Appendix A. Quick Setup SheetPage A.1Device TypePC AT[PS/2]PS/2MacintoshUSBIBM TerminalKeyboardlessCode39 WandEmulationSerial InterfaceTerminal WedgeS

Pagina 30 - Pin Number Signal

Appendix A. Quick Setup SheetPage A.2EAN-8 Default Cut Leading Digit Cut Check Digit EAN-13 Default Cut Leading Digit Cut Check Digit ISBN Conver

Pagina 31 - DB25 Female (Front View)

Page B.1 Appendix B. Function Codes Function Codes for PC F1 (%VA) F3 (%VC) F5 (%VE) F7 (%VG)

Pagina 32 - DB9 Female (Front View)

Page B.2 Function Codes for Macintosh F1 (%VA) F2 (%VB) F3 (%VC) F4 (%VD) F5 (%VE) F6 (%VF) F7 (%VG) F8 (%VH) F9 (%VI) F10 (%VJ)

Pagina 33 - DB25 Male (Front View)

Page C.1 Appendix C. Function Codes for IBM Terminals F1 (%VA) F3 (%VC) F5 (%VE) F7 (%VG)

Pagina 34 - 8.2 Specification

Page 3Chapter 1 OverviewFirst of all, thank you for choosing Unitech’s products. This decoderbuild-in scanner comes in one model and supports interfa

Pagina 35 - UPC-A Conversion

Page D.1Appendix D. Setup MenuD.1 Device Selection and Default: Enter Group 1 Group DefaultDevice ID Device

Pagina 36 - Enable / Disable

Page D.2D.2 Beeps and Delays Enter Group 2 Group Default 0 1 2 3 4 5 6 7 8 9Beep Tone: 0 -- None

Pagina 37 - Appendix B. Function Codes

Page D.3D.3 Keyboard Wedge Settings Enter Group 3 Group Default 0 1 2 3 4 5 6 7 8 9Function Code:

Pagina 38 - Function Codes for Macintosh

Page D.4D.4 RS232 Settings Enter Group 4 Group Default0 1 2 3 4 5 6 7 8 9Baud Rate: 0 -- 300 4 – 480

Pagina 39 - Clear(/FR)

Page D.5D.5 Scanner Port: Enter Group 5 Group Default 0 1 2 3 4 5 6 7 8 9Terminator:0—Enter

Pagina 40 - Appendix D. Setup Menu

Page D.6D.6 Magnetic Reader Enter Group 6 Group Default 0 1 2 3 4 5 6 7 8 9Terminator0—Enter

Pagina 41 - D.2 Beeps and Delays

Page D.7D.7 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128 Enter Group 7 Group Default 0 1 2 3 4 5 6 7

Pagina 42 - D.3 Keyboard Wedge Settings

Page D.8D.8 Code 128 / MSI Code / Code 93 / Codabar/ Label Code: Enter Group 8 Group Default 0 1 2 3 4 5 6

Pagina 43 - D.4 RS232 Settings

Page D.9D.9 UPC / EAN / Delta Code Enter Group 9 Group Default 0 1 2 3 4 5 6 7 8 9UPC-A: 0/1 --

Pagina 44 - D.5 Scanner Port:

Page D.10D.10 Data Editing: Enter Group 10 Group Default0123456789+- Review IN_ID LEN MATCH O-STR “ * # Enter

Pagina 45 - D.6 Magnetic Reader

Page 4Chapter 2 Keyboard InterfaceAs a keyboard Interface, the scanner is actually installed between PC(or terminal) and keyboard. See Figure 1 for re

Pagina 46

Page D.11D.11 Dump Setup Strings:See Section 6.3 for how to use the labels below. Dump Settings Dump Settings on PC/AT

Pagina 47

Page E.1Appendix E. Full ASCII Chart( Characters in parentheses represent Code 39 bar code printing ) NUL (%U) SOH ($A) STX ($B) ETX

Pagina 48 - D.9 UPC / EAN / Delta Code

Page E.2 RS (%D) US (%E) SP ! (/A) ” (/B) # (/C) $ % & (/F) ’ (/G)

Pagina 49 - D.10 Data Editing:

Page E.3 ? (%J) @ (%V)A B C D E F G H IJKLMNOPQRST U

Pagina 50 - D.11 Dump Setup Strings:

Page E.4 ` (%W) a (+A) b (+B) c (+C) d (+D) e (+E) f (+F) g (+G) h (+H) i (+I)

Pagina 51 - Appendix E. Full ASCII Chart

Page F.1Appendix F. Bar Code Test ChartEAN-133 0 45 2 14 83 4 12 3EAN-88 0 12 34 5 3UPC-AUPC-E0 21 2 34 5 799ISBN 957-630-239-09 7895 7 6 3 0 23 9807

Pagina 52

Page 57) If nothing happens at step 6, check all cable connections first andmake sure your PC or terminal has been powered. Contact technicalsupport i

Pagina 53

Page 62.4 Installed as an USB InterfaceYou can install the scanner with the USB interface cable to work witheither PC or iMac USB port. See Figure 1.1

Pagina 54

Page 7your scanning speed, a longer interblock delay may ensure the dataintegrity.Function CodeThe scanner can emulate function and other special keys

Pagina 55 - W+ E + D + G + E

Page 8Chapter 3 RS232 Serial Interface3.1 InstallationTo use the scanner as a RS232 serial interface, a RS232 interface cableand a power adapter are r

Commenti su questo manuale

Nessun commento