PT630 Operation Guide Page 1 of 41 ______________________________________________________ PT630 Portable Terminal Operation Guide
PT630 Operation Guide Page 10 of 41 ______________________________________________________ 3.1.1 NORMAL mode Keyboard of the PT630 is
PT630 Operation Guide Page 11 of 41 ______________________________________________________ 3.2 PT630 Modes of Operation There are thr
PT630 Operation Guide Page 12 of 41 ______________________________________________________ User Mode Commands: Command Usage
PT630 Operation Guide Page 13 of 41 ______________________________________________________ will always be displayed on the LCD screen.
PT630 Operation Guide Page 14 of 41 ______________________________________________________ 3.2.2.4 DIR The DIR command shows RAM disk
PT630 Operation Guide Page 15 of 41 ______________________________________________________ DATE-TIME SETUP1998/01/01 08:00:00 3.2.2.8
PT630 Operation Guide Page 16 of 41 ______________________________________________________ 3.2.2.8.3 DISPLAY Enable/Disable whether
PT630 Operation Guide Page 17 of 41 3.2.3 Supervisor Mode The PT630 Supervisor mode allows the user to configure and validate the PT630 hard
PT630 Operation Guide Page 18 of 41 port. The communication parameters must be set correctly in order to send/receive data via the RS232 port.
PT630 Operation Guide Page 19 of 41 UPC-E Enable/disable decoding (ON) Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND
PT630 Operation Guide Page 2 of 41 ______________________________________________________ CHAPTER 1. INTRODUCTION ...
PT630 Operation Guide Page 20 of 41 Online Use the [] key to toggle between REMOTE and LOCAL, then hit [ENT] to make the selection. REMO
PT630 Operation Guide Page 21 of 41 The second line in the EXEC MENU shows Min and Max number of kilobytes that can be allocated to the Execu
PT630 Operation Guide Page 22 of 41 FormCaching Specification DATA FIELD DEFINITION: maximum field number=8 Category Range Description 1 F
PT630 Operation Guide Page 23 of 41 The PT630 enables FormCaching by default, the following settings also apply: DATA FIELD DEFINITION: field
PT630 Operation Guide Page 24 of 41 POWERONACTIVESTANDPOWERFAILURESHUTDOWNBYpress [PWR]wait onkeyin/scankey inbar code scanRS232 inputpress [P
PT630 Operation Guide Page 25 of 41 3.2.3.7 Initialization The user can command the PT630 to execute a Cold Start that will clear all data s
PT630 Operation Guide Page 26 of 41 WARNING : Before doing any system initialization, please make sure that you have already backup or uplo
PT630 Operation Guide Page 27 of 41 6. SCANNER Connect a bar code scanner to test bar code input by scanning bar code labels. Press any key t
PT630 Operation Guide Page 28 of 41 Chapter 4. HARDWARE OVERVIEW 4.1 INTRODUCTION The PT630 is a handheld data terminal that has an integr
PT630 Operation Guide Page 29 of 41 4.2 FEATURES • 16-bit Microprocessor, 16Mhz Clock • Real Time Clock Integrated Circuit (IC) • 512 KB,
PT630 Operation Guide Page 3 of 41 ______________________________________________________ Chapter 1. Introduction The PT630 is a pro
PT630 Operation Guide Page 30 of 41 4.3.3 PT630 CHARGING/COMMUNICATION CRADLE An optional charging/communication cradle (dock station), mo
PT630 Operation Guide Page 31 of 41 Chapter 5. COMMUNICATION 5.1 INSTALLATION The RS-232 port of PT630 can communicate with the serial por
PT630 Operation Guide Page 32 of 41 5.1.2 REMOTE CONNECTION: The remote connection of PT630 is established by linking a pair of modems throug
PT630 Operation Guide Page 33 of 41 5.2 DOWNLOADING AND UPLOADING The PT630 supports the MULTI protocol and ESC commands for serial data co
PT630 Operation Guide Page 34 of 41 5.2.1 Downloading a Jobgen Pro application from Host to PT630 This function downloads an existent JobGe
PT630 Operation Guide Page 35 of 41 5.2.3 Downloading a file from Host to PT630 using the Kermit Server This function downloads a file from
PT630 Operation Guide Page 36 of 41 5.2.4 Uploading files from PT630 to HOST using the Kermit Server Having collected the data into the PT6
PT630 Operation Guide Page 37 of 41 Chapter 6. Troubleshooting 1. If power-low icon indicator of main battery shown on LCD screen, Plug i
PT630 Operation Guide Page 38 of 41 8. If encounter any other abnormal symptoms, Caution: The following process will clear all data in PT630
PT630 Operation Guide Page 39 of 41 Chapter 7. POWER SOURCES A Li-ion battery provide main power source. A Lithium battery is used to back
PT630 Operation Guide Page 4 of 41 ______________________________________________________ The intelligence level of the terminal is det
PT630 Operation Guide Page 40 of 41 7.1 MAIN/BACKUP BATTERY REPLACEMENT AND INSTALLATION Main Battery 1. Make sure the unit is turned of
PT630 Operation Guide Page 41 of 41 7.2 MAIN POWER BATTERY CHARGING WITH AC/DC ADAPTOR (Regular/Normal Charge) When the PDT shows “Main bat
PT630 Operation Guide Page 42 of 41 7.4 MAIN BATTERY STORAGE & SAFETY PRECAUTIONS Charging Considerations It is important to consider
PT630 Operation Guide Page 5 of 41 ______________________________________________________ 1.2.3 Serial Port Subsystem The PT630 term
PT630 Operation Guide Page 6 of 41 ______________________________________________________ Chapter 2. System Software Organization The
PT630 Operation Guide Page 7 of 41 ______________________________________________________ COM Manager The COM manager controls the com
PT630 Operation Guide Page 8 of 41 ______________________________________________________ requested. The supervisor menu can be request
PT630 Operation Guide Page 9 of 41 ______________________________________________________ Chapter 3. OPERATING MODES 3.1 Keyboard Mo
Commenti su questo manuale